Loading: 0%

testo 316-2 - Gas leak detector

Order-Nr. 0632 3162
  • 18-step bar for displaying gas concentration; additional maximum leakage display

  • Quick reaction time with built-in pump

  • Flexible gooseneck sensor for checking hard-to-reach pipes and places

  • Rechargeable batteries for longer performance

Speedy and sure gas leak detection. The testo 316-2 provides you with a quick and reliable means of detecting methane, propane and hydrogen in the surrounding air. The gas concentration is displayed in the form of an easy-to-read bar and an alarm is triggered when a threshold is crossed.

Product Information
  • Product Detail
  • Product Tech
  • Accessory
  • Download

Product Description

Whether it’s for carrying out checks on flanges, fittings or any other places that are typically prone to leaking, the testo 316-2 gas leak detector provides you with a speedy and sure means of detecting higher concentrations of methane, propane and hydrogen in the surrounding air.

The testo 316-2 gas leak detector. For pinpoint detection of gas leaks

Even if you already know that a pipe is leaking, you normally still have a long way to go before you can actually locate the leak. The testo 316-2 gas leak detector is just the right tool for carrying out such pinpointing detection. The detector’s easy-to-read 18-step bar display and maximum leakage reading show the concentration of combustible gas in the surrounding air and lead you quickly and reliably to the source of the leak. The detector also has an audible alarm that warns you when a threshold is crossed and a headphone jack which allows you to connect earphones for more focused and productive working in loud or distracting environments.

Delivery Scope

testo 316-2 gas leak detector, power adaptor, earphones.

Methane (CH₄)

Measuring range

10 ppm to 4.0 Vol.%

Lower response threshold                               

10 ppm

1st alarm limit

200 ppm

2nd alarm limit

10000 ppm

 

Propane (C₃H₈)

Measuring range

10 ppm to 1.9 Vol.%

Lower response threshold                               

10 ppm

1st alarm limit

100 ppm

2nd alarm limit

5000 ppm

 

Leak detection H₂

Measuring range

10 ppm to 4.0 Vol.%

Lower response threshold                               

10 ppm

1st alarm limit

200 ppm

2nd alarm limit

10000 ppm

 

General technical data

Operating humidity

20 to 80 %RH

Weight

348 g

Reaction time

t₉₀ < 2 s

Dimensions

190 x 57 x 42 (without sensors)

Operating temperature                               

-5 to +50 °C

Heat up time

60 s

Battery type

NiMH battery

Battery life

6 h

Display type

18_segment_bar_display

Storage temperature

-25 to +60 °C

Mains unit

Mains unit 12V / DC / 300 mA