Loading: 0%

testo 330i - flue gas analyzer with NO sensor

Order-Nr. 0632 3000 72
  • On-site digital creation of reports with the testo 330i App

  • Operation independent of measuring location – readings are always available when you need

  • testoFix probe holder (optional) – holds the probe in the centre of flow at all times

  • Particularly robust, completely enclosed plastic housing

Proven technology meets revolutionary operation. The testo 330i flue gas analyzer was specifically developed to help you to overcome all the obstacles you meet when servicing and commissioning heating systems.  

Product Information
  • Product Detail
  • Product Tech
  • Accessory
  • Download

Product Description

The testo 330i flue gas analyzer is an advancement of the testo 330 LL flue gas analyzer. Its proven measuring technology is once again at the heart of the testo 330i. This means that you can rely on highly accurate results when measuring flue gas, draught and O2 supply air. The testo 330i also has the following impressive features:

  • User-replaceable long-life sensors with a service life of up to 6 years

  • Successful TÜV inspection according to the 1st German Federal Immission Control Ordinance (BImSchV) and EN 50379, Parts 1-3

  • ntegrated draught and gas zeroing. This means that the probe does not have to be removed from the flue gas duct for the zeroing

  • Fresh air dilution up to 30,000 ppm upon exceeding a CO threshold value

  • NO sensor for combined heat and power plants

The new testoFix probe holder is available as an accessory, so the flue gas probe is guaranteed not to lose the centre of flow once it has been found. This can be attached to the pipe quickly and easily. It holds the probe in the centre of flow and also serves as a fall-proof suspension system for the testo 330i flue gas analyzer. Incidentally, the hose between probe and measuring instrument is lighter and more flexible than before.

The future of flue gas measuring technology

The testo 330i no longer has a display. How do you make the correct adjustments to the flue gas analyzer? Where can you view the readings? What about the creation of measurement protocols? Via the testo 330i App on your smartphone. The readings are transferred from the testo 330i flue gas analyzer to the App via Bluetooth. So you always have the relevant values to hand whenever you need them. This is particularly useful when faced with larger systems or awkward measuring points as there is no need to look around corners, which can be annoying. The measurement parameters can also be set intuitively, via the App. Once you have completed the measurement, you can add comments or photos of the system to the results on site, and send them to your customer or the office via e-mail.

Requirement: iOS 7.1 / Android 4.3 or newer. Mobile end device with Bluetooth 4.0.

Delivery Scope

testo 330i flue gas analyzer with long-life gas sensors, 3 slots and integrated draught and gas zeroing, including O2/CO measuring cell, NO sensor, rechargeable battery and calibration protocol. 

Differential Pressure - Piezoresistive

Measuring range                               

0 to 300 hPa

Accuracy

±0.5 hPa (0.0 to +50.0 hPa)

±1 % of mv (+50.1 to +100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 hPa

 

Flue gas O₂

Measuring range                               

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

 

CO determination (without H₂-compensation), automatic dilution in testo 320-2 LL

Measuring range

0 to 15000 ppm

Accuracy

±200 ppm or ±20 % of mv (0 to 15000 ppm)

Resolution

1 ppm

 

Flue gas NO

Measuring range                               

0 to 3000 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (101 to 2000 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution

1 ppm

 

Flue gas Draught

Measuring range                               

-9.99 to +40 hPa

Accuracy

±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)

±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution

0.01 hPa

 

Temperature

Measuring range                               

-40 to +1200 °C

Accuracy

±0.5 °C (0.0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °C (-40 to +999.9 °C)

1 °C (Remaining Range)

dependent on the thermocouple

Flue gas degree of effectivity, Eta (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

 

Flue gas loss (calculated)

Measuring range                               

0 to 99.9 %

Resolution

0.1 %

 

Flue gas CO₂ calculation (calculated from O₂)

Measuring range                               

Display range 0 to CO₂ max

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

 

Flue gas CO (without H₂-compensation)

Measuring range                               

0 to 4000 ppm

Accuracy

±20 or ±10 % of mv (0 to 400 )

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

 

General technical data

Dimensions

270 x 160 x 57 mm

Operating temperature                               

-5 to +45 °C

Power supply

Rech. batt. block 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A (optional)

System requirements

requires iOS 7.1 or newer; requires Android 4.3 or newer; requires mobile end device with Bluetooth 4.0

Maximum memory

500000 readings

Storage temperature

-20 to +50 °C

Weight

720 g (excluding battery)

O2-Sensor

O2 sensor for testo 330-1 LL/-2 LL

Order Number: 0393 0002


Connection cable

USB connection cable, instrument-PC

Order Number: 0449 0047


Spare battery 2600 mA

Spare battery 2600 mA

Order Number: 0515 0107


System Case

Instrument case for testo 330i (height: 130 mm)

Order Number: 0516 3302


Large System Case

Instrument case for testo 330i (height: 180 mm)

Order Number: 0516 3303


Calibration certificate

ISO flue gas calibration certificate for flue gas analyzers; calibration at 6 measuring points: O2: 2.5 vol% / CO: 100 ppm / CO: 1000 ppm / NO: 800 ppm / NO2: 100 ppm / SO2: 1000 ppm

Order Number: 0520 0003


Adhesive pockets

Adhesive pockets testo 330-1/-2 LL for printout, paper barcode labels; 50 off

Order Number: 0554 0116


Spare thermal paper

Spare thermal paper for printer, permanent

Order Number: 0554 0568


Hose extension

Hose extension - probe-instrument extension hose (length 2.8 m)

Order Number: 0554 1202


No picture available

Upgrade NO-sensor; 0 to 3000 ppm; resolution 1 ppm

Order Number: 0554 2151


testo Fix

testoFix probe holder

Order Number: 0554 3006


testo BLUETOOTH ® -/IRDA printer

BLUETOOTH®-/IRDA printer with Bluetooth® and IrDA interface for printing out measurement data and graphs from compatible Testo measuring instruments or Testo Apps

Order Number: 0554 0621


Mains unit international

International mains unit

Order Number: 0554 1096


Smoke tester with oil; soot sheet; for measuring soot in flu...

Smoke tester with oil and soot sheet, for measuring soot in flue gas, excl. cone (part no. 0554 9010)

Order Number: 0554 0307


Spare particle filter

Spare dirt filters - for probe handle (10 off)

Order Number: 0554 3385

Other Product