Intuitive: clearly structured measurement menu for long-term measurement and parallel determination of CO₂ concentration, humidity, air temperature and degree of turbulence in workplaces
Precise: calculation of wet bulb temperature, dew point and absolute humidity – determination of the degree of turbulence and draught risk according to EN ISO 7730 / ASHRAE 55
Convenient: wireless probe, internal data storage and USB port for data export
As multifaceted as your challenges themselves: the air velocity and IAQ measuring instrument can be expanded with a large portfolio of digital probes
Thông tin sản phẩm
Chi tiết sản phẩm
Thông số kỹ thuật
Phụ kiện
Download
Product Description
Use this practical Indoor Comfort ComboKit to handle all relevant measurements in order to evaluate the indoor air quality in indoor areas and to determine the draught risk and degree of turbulence in workplaces. The testo 440 air velocity and IAQ measuring instrument, the CO2 probe with Bluetooth® including temperature and humidity sensor and the turbulence probe are all safely stowed away in the case. So you can get down to work straight away!
Temperature - NTC
Measuring range
-40 to +150 °C
Accuracy
±0.4 °C (-40 to -25.1 °C)
±0.3 °C (-25 to +74.9 °C)
±0.4 °C (+75 to +99.9 °C)
±0.5 % of mv (Remaining Range)
Resolution
0.1 °C
Temperature - TC Type K (NiCr-Ni)
Measuring range
-200 to +1370 °C
Accuracy
±(0.3 °C + 0.3 % of mv)
Resolution
0.1 °C
General technical data
Weight
250 g
Dimensions
154 x 65 x 32 mm
Operating temperature
-20 to +50 °C
Product colour
black/orange
Connectable probes
1 x digital probe with cable or 1 x Temperature NTC TUC, 1 x digital Bluetooth probe or testo Smart Probe, 1 x Temperature TC Type K
Battery type
3 AA mignon 1.5 V
Battery life
12 h (typically vane measurement)
Interface
Bluetooth®; USB
Storage temperature
-20 to +50 °C
Temperature - NTC
Measuring range
0 to +50 °C
Accuracy
±0.5 °C
Resolution
0.1 °C
Humidity - Capacitive
Measuring range
5 to 95 %RH
Accuracy
±3 %RH (10 to 35 %RH)
±2 %RH (35 to 65 %RH)
±3 %RH (65 to 90 %RH)
±5 %RH (Remaining Range)
±0.06 %RH/K (0 to +50 °C)
Resolution
0.1 %RH
Please see the additional accuracy information for humidity in the instruction manual.
Absolute Pressure
Measuring range
+700 to +1100 hPa
Accuracy
±3.0 hPa
Resolution
0.1 hPa
Ambient CO₂
Measuring range
0 to 10000 ppm
Accuracy
±(50 ppm + 3 % of mv)
(0 to 5000 ppm)
±(100 ppm + 5 % of mv)
(5001 to 10000 ppm)
Resolution
1 ppm
General technical data
Storage temperature
-20 to +60 °C
Weight
195 g
Dimensions
295 x 50 x 40 mm
Operating temperature
-5 to +50 °C
Length probe shaft
130 mm
Probe head diameter
30 mm
Product colour
black/orange
Battery type
4 x type AA batteries
Battery life
21,5 h
Data transfer
Bluetooth®
Radio range
20 m
Temperature - NTC
Measuring range
0 to +50 °C
Accuracy
±0.5 °C
Resolution
0.1 °C
Absolute Pressure
Measuring range
+700 to +1100 hPa
Accuracy
±3.0 hPa
Resolution
0.1 hPa
Velocity - Hot wire
Measuring range
0 to 5 m/s
Accuracy
±(0.03 m/s + 4 % of mv)
Resolution
0.01 m/s
General technical data
Storage temperature
-20 to +60 °C
Weight
250 g
Dimensions
400 x 90 x 90 mm
Operating temperature
0 to +50 °C
Cable length
1.4 m
Probe head diameter
820 mm
Product colour
black/orange
Standards
EN ISO 7730 / ASHRAE 55
General technical data
Weight
1400 g
Dimensions
516 x 135 x 256 mm
Product colour
Black
BLUETOOTH®-/IRDA printer with Bluetooth® and IrDA interface for printing out measurement data and graphs from compatible Testo measuring instruments or Testo Apps
Order Number: 0554 0621
Measuring tripod for IAQ and comfort level measurements, to ensure standard-compliant, secure positioning of measuring instrument and probes including transport bag
Order Number: 0554 1591
Bluetooth® handle for connecting probe heads: transmits readings conveniently via Bluetooth
Order Number: 0554 1111
Cable handle for connecting probe heads: transmits readings via cable
Order Number: 0554 2222
IAQ data logger for long-term measurements
Order Number: 0577 0400
USB mains unit incl. cable
Order Number: 0554 1105
ISO CO2 calibration certificate; with 3 measuring points: 0 / 1,000 / 5,000 ppm
Order Number: 0520 0033
ISO humidity calibration certificate; with 2 measuring points: 11.3 and 75.3 %RH at +25°C
Order Number: 0520 0006
ISO temperature calibration certificate for air/immersion probes; with 1 measuring point: 0 °C
Order Number: 0520 0062
ISO calibration certificate for pressure; calibration at 3 measuring points, distributed over the measuring range of the measuring instrument/probe – accuracy 0.1 to 0.6 % of f.v.
Order Number: 0520 0085
ISO pressure calibration certificate; with 5 measuring points distributed over the measuring range; accuracy > 0.6 % of f.v.
Order Number: 0520 0005
DAkkS pressure calibration certificate; with 9 measuring points distributed over the measuring range, accuracy 0.1 to 0.6 % of f.v.
Order Number: 0520 0215
DAkkS pressure calibration certificate; with 5 measuring points distributed over the measuring range, accuracy > 0.6 % of f.v.
Order Number: 0520 0225
ISO flow calibration certificate for hot wire and vane anemometers; with 4 measuring points: 0.3 / 0.5 / 0.8 / 1.5 m/s
Order Number: 0520 0024
DAkkS flow calibration certificate for hot wire and vane anemometers; with 5 measuring points: 0.1 / 0.2 / 0.5 / 0.8 / 1 m/s
Order Number: 0520 0224
16 mm vane probe head including temperature sensor; for attachment to extendable telescope for air velocity probes with universal handle – measuring range +0.6 to +50 m/s, -10 to +70 °C
Order Number: 0635 9570
High-precision 100 mm vane probe head including temperature sensor: for attachment to extendable telescope for air velocity probes with universal handle or to a universal Bluetooth® or cable handle – measuring range +0.1 to +15 m/s, -20 to +70 °C
Order Number: 0635 9370
100 mm vane probe head: for attachment to extendable telescope for air velocity probes with universal handle or to universal Bluetooth® or cable handle – measuring range +0.3 to +35 m/s, -20 to +70 °C
Order Number: 0635 9430
Hot wire probe head including temperature and humidity sensor: for attachment to extendable telescope for air velocity probes with universal handle – measuring range 0 to +50 m/s, -20 to +70 °C, 5 to 95% RH
Order Number: 0635 1570
Humidity/temperature probe head: for attachment to universal Bluetooth® or cable handle – accuracy ±2% RH / ±0.5 °C, measuring range 0 to 100% RH / -20 to +70 °C
Order Number: 0636 9730
High-precision humidity/temperature probe head: for attachment to a universal Bluetooth® or cable handle – accuracy: ±(0.6% RH + 0.7 % of m.v.) (0 to 90% RH) / ±0.3 °C (+15 to +30 °C)
Order Number: 0636 9770
CO₂ probe head including temperature and humidity sensor: for attachment to universal Bluetooth® or cable handle – measuring range 0 to 10,000 ppm, -10 to +50 °C, 5 to 95% RH
Order Number: 0632 1550
CO probe head: for attachment to universal Bluetooth® or cable handle – measuring range 0 to 500 ppm
Order Number: 0632 1270
Combi-case for testo 440 and multiple probes; for protecting and transporting the testo 440 (dP) air velocity and IAQ measuring instrument and multiple probes
Order Number: 0516 4401
Service case for volume flow measurement; for protecting and transporting the testo 440 (dP) air velocity and IAQ measuring instrument, probes and accessories for measuring volume flow